ZERO CLAMP FOR BZO 3 AsXs
 P4 – NILED
Technical informations
To connect the lighting lamp to the neutral wire of an insulated line. For use in the internal power line connection.
Installation recommendations
- Use a socket or ring wrench to mount the clamp.
 - Push the branch hose all the way into the sealing cap.
 - Tighten the screw to break the head. Breaking the screw head guarantees a proper connection.
 - When removing the clamp, loosen the screw with a wrench.
 - The disassembled clamp is not reusable.
 
  
  Advantages
- Ensured tightness of the connection (6kV test under water
 - Installation without a torque wrench - Correct clamping torque ensured by the self-tapping screw head
 - Clamps made of materials resistant to corrosion and UV radiation
 - Terminals designed for work on AL, Cu cables
 
Technical data
- Main cable Al: 6-95 mm2
 - Branch cable: 1.5-6 mm2
 - Tightening torque 6 (breaking the screw head)
 - Key size 10 10
 
Notes: double-piercing